Study on the origin of linear deviation with the Beer-Lambert law in absorption spectroscopy by measuring sulfur
Linying Li1, Huan Zhao1, Nan Ni1
1School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, PR China.
Abstract:
In accordance with the Beer-Lambert law, absorbance is proportional to concentration and optical path length of the absorbers in the sample, and in a linear relationship with total column concentration (product of concentration and optical path length) at a single wavelength. However, limitation of spectral resolution will result in linear deviation with the Beer-Lambert law in actual measurement. Regarding additivity of polychromatic light intensity as the theoretical basis, this paper attributed linear deviation with the Beer-Lambert law to spectral resolution, concentration and light intensity, and verified this explanation by measuring sulfur dioxide at various total column concentrations using spectrometers with different spectral resolutions in the waveband range of 216-230 nm. It was found that linear deviation with the Beer-Lambert law was in negative correlation with spectral resolution, and in positive correlation with total column concentration, and absorbance could be considered to be linear with total column concentration (below 171.4 mg/m2) of sulfur dioxide in the wavelength range of 216-230 nm. In addition, it was also proved that linear deviation increases with decreasing light intensity at a fixed sulfur dioxide column concentration.
More Related Videos
07:49Characterizing Lewis Pairs Using Titration Coupled with In Situ Infrared Spectroscopy
Published on: February 20, 2020
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
UV–Vis Spectroscopy: Beer–Lambert Law
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
UV–Vis Spectrometers
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...