Soft variable structure control of linear fractional-order systems with actuators saturation
Related Experiment Video
Updated: Sep 28, 2025

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Ebrahim Abbaszadeh1, Mohammad Haddad-Zarif1
1Department of Electrical and Robotic Engineering, Shahrood University of Technology, Shahrood, Iran.
Abstract:
In this paper, a new method of soft variable structure control for Fractional-Order System (FOS) is proposed to achieve faster response while the control signal is continuous and satisfies actuators' constraints. Our proposed method, by describing a desired commensurate FOS, with the help of a pole placement algorithm and applying an optimization routine, in the form of a procedure, leads the system to the desired character. The routine is done by solving an optimization problem subject to a control signal constraint qua we obtain the fastest response possible in the sense of stability region. The sufficient condition of stability of the control system is developed based on the stability theory of Fractional Order (FO) linear differential equations, and attributes of the Mittag-Leffler function. Finally, an example and corresponding numerical simulations are presented to show the efficiency of the proposed method. In the proposed method, a new control strategy for the FOS is presented, a complex problem is solved in a simple way, and it can exploit the benefits of using FOS in the modeling and control of complex physical phenomena.
More Related Videos
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Second Order systems II
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...