Related Experiment Video
Updated: Sep 28, 2025

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Lateral flow immunoassay with peptide-functionalized gold nanoparticles for rapid detection of protein tyrosine
Xiaotong Li1, Qunyan Zhu2, Fengqin Xu1
1State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Jinzhai Road Baohe District, Hefei, Anhui, 230026, China.
Abstract:
In this work, a lateral flow immunoassay (LFIA) with peptide functionalized gold nanoparticles (termed as biotin-ppeptide-AuNPs) has been developed for rapid, semi-quantitative detection of PTP1B activity without using any sophisticated equipment. In this method, the anti-phosphotyrosine (anti-pY) monoclonal antibody and streptavidin were used as test line and control line, respectively. The biotin-ppeptide-AuNPs contain 10% biotinylated peptide ligand carry a motif SDGHEpYIYVDP with pY (phosphotyrosine) and 90% pentapeptide (CALNN) ligand, which are used as PTP1B substrates and LFIA labelling probes. The experimental results demonstrate that the as-proposed LFIA with biotin-ppeptide-AuNPs exhibits a wide linear range (from 50 ng/mL to 10 μg/mL), a relatively low limit of detection (LOD, 44 ng/mL), and good specificity. In addition, the LFIA with biotin-ppeptide-AuNPs has been successfully used to evaluate activity levels of PTP1B in four cell lysates and the detection results exhibit a consistent trend with that of commercial kit.