Related Experiment Video
Updated: Sep 28, 2025

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Disinfection of Orthodontic Elastomers and Its Effects on Tensile Strength
Leandro Berni Osorio1, Luiz Makito Osawa Gutierrez2, Eduardo Martinelli de Lima2
1Department of Stomatology, School of Dentistry, Federal University of Santa Maria, Rio Grande do Sul, Brazil.
Objective:
This study aimed to investigate the effect of different disinfection protocols on the mechanical properties of orthodontic elastomeric ligatures (EL), an important issue to biosafety improvement and infection control, and to avoid cross-contamination.
Methods:
A total of 120 EL were randomly divided into 6 experimental groups (n = 20) according to the disinfection method employed: group 1, EL were not immersed in a disinfectant solution (control group); group 2, EL were immersed in 2% glutaraldehyde; group 3, EL were immersed in 70% alcohol solution; group 4, EL were cleaned in an ultrasound washing (UW) machine by immersion in 0.5% enzyme detergent solution; group 5, UW procedure was performed, followed by immersion in 2% glutaraldehyde; Group 6, UW procedure was performed, followed by immersion in 70% alcohol. After disinfection, EL were subjected to a tensile strength test where the maximum strength, maximum elongation, and work at failure were determined. Data were statistically evaluated using one-way ANOVA and Dunnett's t-test for multiple comparisons.
Results:
Statistically significant different (P < .05) values were found between the disinfection methods, and 70% alcohol showed negative changes in all mechanical properties of orthodontic elastomers. By contrast, 2% glutaraldehyde did not show significant alteration in mechanical properties, whereas the UW procedure showed significant alteration in maximum strength and work at failure.
Conclusion:
Of the tested substances for disinfection, 2% glutaraldehyde was the only substance that did not cause significant changes in the mechanical properties of orthodontic elastics and is considered as an alternative for elastic disinfection before its use.
More Related Videos
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
04:51Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment
Published on: March 1, 2024