Related Experiment Video For CT-guided
Updated: Sep 28, 2025

Using 22C3 Anti-PD-L1 Antibody Concentrate on Biopsy and Cytology Samples from Non-small Cell Lung Cancer Patients
Published on: September 25, 2018
Comparison of the Detection Rates of Different Diagnostic Methods for Primary Peripheral Lung Cancer
Lijuan Sun1, Chao Qin1, Qun Fu1
1Department of Respiratory Medicine, The Fifth Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Objective:
The present study aims to compare the detection rates of different diagnostic methods for primary peripheral lung cancer (PPLC).
Methods:
The detection rate and patient information were collected from a total of 359 cases of PPLC or a suspected diagnosis of lung cancer; among these, 186 cases were simultaneously treated with fibreoptic bronchoscopy, brush inspection and flush inspection, and 173 cases underwent a computed tomography (CT)-guided percutaneous lung biopsy (PNB). The positive detection rates of the different methods were compared.
Results:
In the detection of peripheral lesions (diameter of <5 cm), the CT-PNB had the significantly highest detection rate, followed by the combined basic method (fibreoptic bronchoscopy + brushing + flushing). The independent use of the three basic sampling methods showed a significantly lower detection rate compared with the combined use.
Conclusion:
In the diagnosis of peripheral lung cancer, the CT-PNB had the best detection rate; hence, it could be used in clinical practice for the diagnosis of such lesions.