Related Experiment Video
Updated: Sep 28, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
In-vivo dose determination in a human after radon exposure: proof of principle
Franziska Papenfuß1, Andreas Maier1, Claudia Fournier1
1GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291, Darmstadt, Germany.
Abstract:
Radon-222 is pervasive in our environment and the second leading cause of lung cancer induction after smoking while it is simultaneously used to mediate anti-inflammatory effects. During exposure, radon gas distributes inhomogeneously in the body, making a spatially resolved dose quantification necessary to link physical exposure conditions with accompanying risks and beneficial effects. Current dose predictions rely on biokinetic models based on scarce input data from animal experiments and indirect exhalation measurements of a limited number of humans, which shows the need for further experimental verification. We present direct measurements of radon decay in the abdomen and thorax after inhalation as proof of principle in one patient. At both sites, most of the incorporated radon is removed within ~ 3 h, whereas a smaller fraction is retained longer and accounts for most of the deposited energy. The obtained absorbed dose values were [Formula: see text] µGy (abdomen, radon gas) and [Formula: see text] µGy (thorax, radon and progeny) for a one-hour reference exposure at a radon activity concentration of 55 kBq m-3. The accumulation of long-retained radon in the abdomen leads to higher dose values at that site than in the thorax. Contrasting prior work, our measurements are performed directly at specific body sites, i.e. thorax and abdomen, which allows for direct spatial distinction of radon kinetics in the body. They show more incorporated and retained radon than current approaches predict, suggesting higher doses. Although obtained only from one person, our data may thus represent a challenge for the barely experimentally benchmarked biokinetic dose assessment model.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
11:24Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation
Published on: July 3, 2015
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...