Related Experiment Video
Updated: Sep 28, 2025

Species Determination and Quantitation in Mixtures Using MRM Mass Spectrometry of Peptides Applied to Meat Authentication
Published on: September 20, 2016
Use of MALDI-TOF MS technology to evaluate adulteration of small ruminant milk with raw bovine milk
L Rysova1, P Cejnar2, O Hanus3
1Department of Food Science, Czech University of Life Sciences Prague, Kamycka 129, 165 00 Prague-Suchdol, Czech Republic.
Abstract:
Detection of adulteration of small ruminant milk is very important for health and commercial reasons. New analytical and cost-effective methods need to be developed to detect new adulteration practices. In this work, we aimed to explore the ability of the MALDI-TOF mass spectrometry to detect bovine milk in caprine and ovine milk using samples from 18 dairy farms. Different levels of adulteration (0.5, 1, 5, 10, 20, 40, 60, and 80%) were analyzed during the lactation period of goat and sheep (in May, from 60 to 90 d in milk, and in August, from 150 to 180 d in milk). Two different ranges of peptide-protein spectra (500-4,000 Da; 4-20 kDa) were used to establish a calibration model for predicting the concentration of adulterant using partial least squares and generalized linear model with lasso regularization. The low molecular weight part of the spectra together with the generalized linear model with lasso regularization regression model appeared to have greater potential for our aim of detection of adulteration of small ruminants' milk. The subsequent prediction model was able to predict the concentration of bovine milk in caprine milk with a root mean square error of 11.4 and 17.0% in ovine milk. The results offer compelling evidence that MALDI-TOF can detect the adulteration of small ruminants' milk. However, the method is severely limited by (1) the complexity of the milk proteome resulting from the adulteration technique, (2) the potential degradation of thermolabile proteins, and (3) the genetic variability of tested samples. Additionally, the root mean square error of prediction based only on one individual sample adulteration series can drop down to 6.34% for quantification of adulterated caprine milk and 6.28% for adulterated ovine milk for the full set of concentrations or down to 2.33 and 4.00%, respectively, if we restrict only to low concentrations of adulteration (0, 0.5, 1, 5, 10%).
More Related Videos
06:34Identification of Rare Bacterial Pathogens by 16S rRNA Gene Sequencing and MALDI-TOF MS
Published on: July 11, 2016
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...