Introduction:
Although anticoagulation therapy is mandated after implantation of a left ventricular assist device (LVAD), postoperative bleedings and reoperations occur relatively frequently and are associated with worse outcomes. We evaluated the use of a conservative postoperative anticoagulation protocol in patients implanted with a HeartMate 3 (HM3) LVAD.
Methods:
In a single-centre retrospective analysis of postoperative outcomes after HM3 LVAD implantation, a standard (old) anticoagulation protocol (i.e. early, full-dose anticoagulation with low-molecular weight heparin and overlapping vitamin K antagonist) was compared with a new conservative anticoagulation protocol (i.e. slow initiation of vitamin K antagonists without overlapping heparin). Main outcomes were changes in international normalised ratio (INR), lactate dehydrogenase (LDH), bleeding and/or tamponade events requiring reoperation, length of stay and adverse events.
Results:
In total, 73 patients (48 in old vs 25 in new protocol group) were evaluated. Mean age was 56 years (standard deviation 13) and most patients (78%) were males. Changes in INR and LDH in the first 14 days were similar in both groups (p = 0.50 and p = 0.997 for interaction, respectively). Number of bleeding/tamponade events requiring reoperation was lower in the new than in the old protocol group (4% vs 33%, p = 0.005). Postoperative 30-day mortality was similar, and we observed no thromboembolic events. Median (25th-75th percentiles) total length of postoperative hospital stay (27 (25-41) vs 21 (19-27) days, p < 0.001) and length of intensive care unit stay (5 (2-9) vs 2 (2-5) days, p = 0.022) were significantly shorter in the new protocol group.
Conclusion:
These retrospective data suggest that conservative slow initiation of anticoagulation therapy after HM3 LVAD implantation is associated with less bleeding/tamponade events requiring reoperation, a similar safety profile and a shorter duration of stay than the currently advised standard anticoagulation protocol.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Mitral Stenosis III: Medical Management
Venous Thrombosis III: Interprofessional Care
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiac Catheterization IV: Nursing Management
Mitral Regurgitation III: Medical Management