Related Experiment Video
Updated: Sep 27, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Application of tight-fitting half-facepiece breath-response powered air-purifying respirator for internal body
Shingo Sekoguchi1, Hajime Ando1, Kazunori Ikegami1
1Department of Work Systems and Health, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Kitakyushu, Fukuoka, Japan.
Abstract:
In dust-generating scenarios in occupational environments, it is important to take measures to prevent not only pneumoconiosis, but also heatstroke. The aim of this study was to verify whether using a tight-fitting half-facepiece breath-response powered air-purifying respirator (PAPR) in combination with a self-produced cooling device could abate the deep body temperature while performing activities. We conducted a crossover study involving 10 subjects. The subjects were subjected to three conditions: wearing a PAPR equipped with a cooling device, PAPR, or a replaceable particulate respirator. During the experiment, the rectal temperature of the subjects was measured, along with the temperature near the PAPR inlet in container with the cooling device when the PAPR equipped with the cooling device was worn. The subjects rested in a cold chamber set at a dry-bulb temperature of 28°C and relative humidity of 45% for 20 min. Then, they moved to a hot chamber set to a dry-bulb temperature of 36°C (with the same relative humidity) in 5 min and exercised on a cycle ergometer for 30 min. After that, the subjects moved to the cold chamber for 5 min and rested for 20 min. Notably, the air inhaled by the subjects wearing PAPR equipped with the cooling device was approximately 10°C cooler than the ambient air. Furthermore, 35 min after the initiation of the experiment (after the middle of the exercise period), the rectal temperature of the participants wearing the PAPR equipped with the cooling device was lower than of those wearing PAPR or replaceable particulate respirators (p <0.05). Thus, we could deduce that the self-produced cooling device was useful in abating deep body temperature. PAPR is useful for its potential applications in hot occupational environments and can save lives in working environments where heat stress can result in major medical complications.
More Related Videos
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Personal Protective Equipment
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Decreased Body Temperature