Parallel Operation of Electron Ionization and Chemical Ionization for GC-MS Using a Single TOF Mass Analyzer
Steffen Bräkling1,2, Kai Kroll2, Carsten Stoermer1
1TOFWERK, Thun 3645, Switzerland.
Abstract:
This work describes a novel mass spectrometer coupled to gas chromatography (GC-MS) that simultaneously displays the mass spectral information of electron (EI)- and chemical ionization (CI)-generated ion populations for a single chromatographic peak. After GC separation, the eluent is equally split and supplied in parallel to an EI and a novel CI source, both operating continuously. Precise switching of the ion optics provides the exact timing to consecutively extract the respective ion population from both sources and transfer them into a time-of-flight (TOF) mass analyzer. This technique enables the acquisition of complementary information from both ion populations (EI and CI) within a single chromatographic run and with sufficient data points to retain the chromatographic fidelity. The carefully designed GC transfer setup, fast ion optical switching, and synchronized TOF data acquisition system provide an automatic and straightforward spectral alignment of two ion populations. With an eluent split ratio of about 50% between the two ion sources, instrument detection limits of <40 fg on the column (octafluoronaphthalene) for the EI and <2 pg (benzophenone) for the CI source were obtained. The system performance and the additional analytical value for compound identification are demonstrated by means of different common GC standard mixtures and a commercial perfume sample of unknown composition.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Analyzers: Common Types
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometers