Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis
Torsten Diekhoff1, Kay Geert A Hermann2, Robert G Lambert3
1Department of Radiology (CCM), Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität Zu Berlin, Freie Universität Berlin, Charitéplatz 1, 10117, Berlin, Germany. torsten.diekhoff@charite.de.
Purpose Of Review:
Recent technical advances in computed tomography (CT) such as low-dose CT and dual-energy techniques open new applications for this imaging modality in clinical practice and for research purposes. This article will discuss the latest innovations and give a perspective on future developments.
Recent Findings:
Low-dose CT has increasingly been used for assessing structural changes at the sacroiliac joints and the spine. It has developed into a method with similar or even lower radiation exposure than radiography while outperforming radiography for lesion detection. Despite being incompatible with low-dose scanning, some studies have shown that dual-energy CT can provide additional information that is otherwise only assessable with magnetic resonance imaging (MRI). However, it is unclear whether this additional information is reliable enough and if it would justify the additional radiation exposure, i.e. whether the performance of dual-energy CT is close enough to MRI to replace it in clinical practice. While the role of dual-energy CT in patients with axial spondyloarthritis remains to be established, low-dose CT has developed to an appropriate modality that should replace radiography in many circumstances and might supplement MRI.
More Related Videos
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies III: Computed Tomography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
