Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Online solid-phase extraction-inductively coupled plasma-quadrupole mass spectrometric quantification of 90Sr using
Kayo Yanagisawa1, Mizuki Odashima1, Makoto Matsueda2
1Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima, 960-1296, Japan.
Abstract:
Due to the lack of a correlation with the natural Strontium (Sr) isotopes, it is difficult to apply the isotope dilution (ID) method to an artificial radioactive mononuclide Strontium-90 (90Sr), in inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS). Meanwhile, online solid-phase extraction (SPE)-ICP-QMS (SPE-ICP-QMS) serves as an automatic sequential analytical technique for measuring the ultra-trace amounts of radionuclides; however, apparent assay values obtained using this method are often negatively affected by differences in the sample matrix composition between standard and actual samples. In this study, the pg L-1 level of 90Sr was successfully measured by combining online SPE-ICP-QMS and the ID method with 88Sr/86Sr ratios in one sample injection, without the radioactive standard. Although naturally occurring abundant isobaric 90Zr significantly influences 90Sr quantification during mass spectrometry, consecutive separations between automated SPE and dynamic reaction cell (DRC) oxidation enable 90Sr quantification, even in the presence of isobaric 90Zr (acceptable down to 5.7 × 10-9 of 90Sr/Zr in sample solution), using this method. Through this method, both radioactive 90Sr and naturally occurring Sr were simultaneously quantified using 88Sr-to-86Sr and 88Sr-to-90Sr ratios without radioactive 90Sr standard solutions. This simultaneous quantification of stable Sr and 90Sr was achieved within 15 min with good recovery rates. The limit of detection of 90Sr was 1.1 pg L-1 (equivalent to radioactivity 5.6 Bq L-1) for a 10 mL injection. Finally, water collected from an actual contaminated water storage tank at the Fukushima Daiichi Nuclear Power Plant (Fukushima, Japan) was analyzed using the proposed method, and the obtained results agreed well with those obtained using conventional analytical methods.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
08:46Dose Uptake of Platinum- and Ruthenium-based Compound Exposure in Zebrafish by Inductively Coupled Plasma Mass Spectrometry with Broader Applications
Published on: April 21, 2022
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences