Related Experiment Video
Updated: Sep 27, 2025

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Power output and hearing performance in osseointegrated auditory devices
Jordi Calvo-Gómez1, Ignacio Pla-Gil1, Emilia Latorre Monteagudo1
1Servicio de Otorrinolaringologia, Hospital Clínico Universitario de Valencia, Universidad de Valencia, Valencia, Spain.
Background And Objective:
Osseointegrated auditory devices are hearing gadgets that use the bone conduction of sound to produce hearing improvement. The mechanisms and factors that contribute to this sound transmission have been widely studied, however, there are other aspects that remain unknown, for instance, the influence of the processor power output. The aim of this study was to know if there is any relationship between the power output created by the devices and the hearing improvement that they achieve.
Materials Y Methods:
44 patients were implanted with a percutaneous Baha® 5 model. Hearing thresholds in pure tone audiometry, free-field audiometry, and speech recognition (in quiet and in noise) were measured pre and postoperatively in each patient. The direct bone conduction thresholds and the power output values from the processors were also obtained.
Results:
The pure tone average threshold in free field was 39.29 dB (SD = 9.15), so that the mean gain was 29.18 dB (SD = 10.13) with the device. This involved an air-bone gap closure in 63.64% of patients. The pure tone average threshold in direct bone conduction was 27.6 dB (SD = 10.91), which was 8.4 dB better than the pure tone average threshold via bone conduction. The mean gain in speech recognition was 39.15% (SD = 23.98) at 40 dB and 36.66% (SD = 26.76) at 60 dB. The mean gain in the signal-to-noise ratio was -5.9 dB (SD = 4.32). On the other hand, the mean power output values were 27.95 dB µN (SD = 6.51) in G40 and 26.22 dB µN (SD = 6.49) in G60. When analysing the relationship between bone conduction thresholds and G40 and G60 values, a correlation from the frequency of 1000 Hz was observed. However, no statistically significant association between power output, functional gain or speech recognition gain was found.
Conclusions:
The osseointegrated auditory devices generate hearing improvement in tonal thresholds and speech recognition, even in noise. Most patients closed the air-bone gap with the device. There is a direct relationship between the bone conduction threshold and the power output values from the processor, but only in mid and high frequencies. However, the relationship between power output and gain in speech recognition is weaker. Further investigation of contributing factors is necessary.
More Related Videos
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
The Auditory Ossicles
The aptly named stapes look very much like a stirrup. The three ossicles are unique to mammals, and each plays a role in...
Hearing
The Cochlea
Auditory Pathway
When viewed cross-sectionally, the cochlea reveals the scala vestibuli and scala tympani flanking...
Anatomy of the Ear