Related Experiment Video
Updated: Sep 27, 2025

Reliable Mechanochemistry: Protocols for Reproducible Outcomes of Neat and Liquid Assisted Ball-mill Grinding Experiments
Published on: January 23, 2018
Exploring bulk volume, particle size and particle motion definitions to increase the predictive ability of in vitro
Marina Navas-Bachiller1, Tim Persoons2, Deirdre M D'Arcy1
1School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin, Ireland.
Abstract:
The definition of the local dissolution environment is central to accurate particle dissolution simulation, and is determined by the apparatus and conditions used. In the flow-through apparatus dissolution occurs in the cell, often in a low velocity environment, with the reservoir considered the relevant volume for dissolution kinetics. Dissolution simulations were conducted using a reduced-order model based on the Ranz-Marshall correlation for mass transfer from spherical particles. Using ibuprofen as a model drug, the effect of defining a local volume to simulate dynamic bulk concentration conditions in the flow-through and paddle apparatus was assessed by comparing use of a near particle volume (NPV), extending a distance of one radius from the particle surface, with a flow-through apparatus cell volume or paddle apparatus vessel volume as the relevant instantaneous volume for dissolution. The instantaneous inlet concentration to NPV or cell volume is the reservoir/vessel concentration at that simulation time point, reflecting the continuous input to the cell of more dilute solution from the reservoir (closed system). Additionally, inputting particle size distribution (PSD) instead of a median particle size (MPS) and enabling or disabling particle motion were investigated, in two media (resulting in low and high solubility) and with two fluid velocity conditions in each apparatus. The NPV predicted effects of fluid velocity differences on dissolution in the high solubility medium in the flow-through apparatus, but had no effect on predictive ability in the paddle apparatus. In both apparatuses, simulations were reasonable for the high solubility environment but underpredicted dissolution in the low solubility environment. The PSD option and disabling particle motion increased the predictive ability of the simulations in low solubility media in the flow-through apparatus. The results highlight the necessity to incorporate the local dynamic dissolution conditions in the flow-through apparatus for accurate dissolution simulation, and the challenges of defining an effective particle size for dissolution simulation and of reflecting hydrodynamic complexity in simulating dissolution in the paddle apparatus.
More Related Videos
Related Concept Videos
Theories of Dissolution: Diffusion Layer Model
This process starts with a thin layer, saturated with the drug, forming at the interface between the solid and liquid. The solute then diffuses from this layer into the main solution. The Noyes-Whitney equation suggests that the rate of dissolution relies on the diffusion...
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Theories of Dissolution: The Danckwerts' Model and Interfacial Barrier Model
Factors Influencing Drug Absorption: Drug Dissolution
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Factors Affecting Dissolution: Drug Permeability, Stability and Stereochemistry

