Analytical Quality by Design Based Systematic Development and Optimization of a Sensitive Bioanalytical Method for
Sudhanshu Bhusan Routray1, Chinam Niranjan Patra1, Suryakanta Swain2
1Department of Pharmaceutics, Roland Institute of Pharmaceutical Sciences, Affiliated to Biju Patnaik University of Technology, Rourkela, Odisha, India.
A new Quality by Design (QbD) enabled reverse-phase Ultra-Fast Liquid Chromatography (RP-UFLC) method simplifies cinacalcet HCl analysis in serum and blood. This robust and accurate method is suitable for routine quality control and pharmacokinetic studies.
Area of Science:
- Analytical Chemistry
- Pharmaceutical Analysis
Background:
- Estimating cinacalcet HCl in biological samples like serum lacks straightforward methods.
- Developing a reliable analytical technique is crucial for therapeutic drug monitoring and research.
Purpose of the Study:
- To develop and validate a simple, precise, and rapid Quality by Design (QbD) enabled reverse-phase Ultra-Fast Liquid Chromatography (RP-UFLC) method.
- To quantify cinacalcet HCl in both solution and biological matrices such as blood.
Main Methods:
- Optimization of critical method parameters (mobile phase composition, flow rate, injection volume) using a Box-Behnken design and response surface methodology.
- Utilized a C18 column with an acetonitrile and Tetrabutyl Ammonium Hydrogen Sulphate mobile phase, flow rate of 1 mL/min, and UV detection at 223 nm.
- Method validation included specificity, linearity, accuracy, precision, and sensitivity assessments.
Main Results:
- The optimized method achieved a retention time of 4.3 minutes with no interfering peaks, demonstrating specificity.
- High accuracy (96.83%-101.32% recovery) and precision (RSD < 2.12%) were observed.
- The method exhibited excellent linearity (R² = 0.999) over a wide concentration range (100-100,000 ng/mL) and sensitive detection limits.
Conclusions:
- The developed QbD-enabled RP-UFLC method is robust, accurate, and cost-effective for cinacalcet HCl analysis.
- The method is suitable for routine quality control in research laboratories and for pharmacokinetic studies.
- This validated method addresses the need for a straightforward analytical approach for cinacalcet HCl in biological samples.