A novel operator-independent noninvasive device for assessing arterial reactivity
Kellen A Knowles1, Kerry J Stewart2, Joseph Tejan1
1Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States.
Background:
Endothelial dysfunction is associated with increased risk of cardiovascular disease (CVD). Currently available noninvasive methods of measuring endothelial function have limitations. We tested a novel device that provides an automated measurement of the difference between baseline and post-ischemic, hyperemia-induced, brachial arterial compliance, a phenomenon known to be endothelium-dependent. The association between the calculated index, Flow-mediated Compliance Response (FCR), and established CVD risk indices was determined.
Methods:
Adults with CVD risk factors or known coronary artery disease (CAD) were enrolled. Framingham Risk Score (FRS) was calculated and presence of metabolic syndrome (MetSyn) was assessed. Carotid artery plaques were identified by ultrasound. Cardiorespiratory fitness was assessed by 6-minute walk test (6MWT). FCR was measured using the device.
Results:
Among 135 participants, mean age 49.3 +/- 17.9 years, characteristics included: 48% female, 7% smokers, 7% CAD, 10% type 2 diabetes, 34% MetSyn, and 38% with carotid plaque. Those with MetSyn had 24% lower FCR than those without (p < 0.001). Lower FCR was associated with higher FRS percentile (r = -0.29, p < 0.001), more MetSyn factors (r = -0.30, p < 0.001), more carotid plaques (r = -0.22, p = 0.01), and lower 6MWT (r = 0.34, p < 0.0001).
Conclusion:
FCR, an index of arterial reactivity obtained automatically using a novel, operator-independent device, was inversely associated with established CVD risk indices, increased number of carotid plaques, and lower cardiorespiratory fitness. Whether measuring FCR could play a role in screening for CVD risk and assessing whether endothelial function changes in response to treatments aimed at CVD risk reduction, warrants further study.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of blood pressure in brachial artery(two-step method)
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: