Immediate Effect of Mechanical Ventilation Mode and Sedative Infusion on Measured Diaphragm Thickness
Steven D Pearson1, Julie Lin2, Matthew R Stutz1
1Section of Pulmonary and Critical Care Medicine, Department of Medicine, University of Chicago, Chicago, Illinois.
Abstract:
Rationale: In patients who are mechanically ventilated, diaphragm thinning on ultrasound is thought to correlate with diaphragm atrophy and has been associated with prolonged intubation. Factors other than atrophy, however, may cause changes in diaphragm thickness, which may confound studies examining changes in diaphragm thickness over time. Objectives: To determine if changes in the mode of mechanical ventilation or an interruption of sedatives have immediate effects on diaphragm thickness measurements in adult patients in the intensive care unit who are mechanically ventilated. Methods: Adult patients receiving invasive mechanical ventilation for less than 48 hours were included. Diaphragm thickness was measured at end-expiration and peak inspiration using ultrasound while patients were receiving both volume assist-control and pressure-support modes in a randomized crossover fashion. In patients receiving sedatives, additional measurements were taken after an interruption of sedatives. Measurements were compared between modes and on assist-control before and after an interruption of sedatives. Results: Of 85 patients enrolled, 66 had measurements on assist-control and spontaneous modes, and 40 had measurements before and after an interruption of sedatives. End-expiratory diaphragm thickness increased by a median of 0.08 mm after an interruption of sedatives (95% confidence interval [CI], 0.002 mm to 0.164 mm; P = 0.017), corresponding to a median increase of 6.5%. No difference was seen when comparing measurements taken on volume assist-control and pressure support (median difference, 0 mm; 95% CI, -0.07 mm to 0.08 mm; P = 0.98). Conclusions: End-expiratory diaphragm thickness increased by 6.5% after an interruption of sedatives. The effect of sedatives on measured diaphragm thickness should be considered in future studies examining changes in diaphragm thickness over time. Clinical trial registered with Clinicaltrials.gov (NCT04319939).
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...