Prediction of Pile Shaft Capacity in Tension Based on Some Direct CPT Methods-Vistula Marshland Test Site
Łukasz Zwara1, Lech Bałachowski1
1Department of Geotechnical and Hydraulic Engineering, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233 Gdańsk, Poland.
Abstract:
This paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with a diameter of 0.4 m and the length varied from 8 m to 14.6 m were subjected to static load tests in tension. Their results were used to determine the ultimate bearing capacity of the reference piles. The pile shaft resistance was estimated according to the AFNOR standard, Doan and Lehane 2018 centrifuge tests based method (Delft University of Technology approach), the Modified Unicone method, KTRI (Kajima Technical Research Institute) and LCPC (Laboratoire Central des Ponts et Chaussées) method. Then, the ultimate bearing capacity determined in static load tests was compared to the estimated values according to five different methods. The best estimation, fitting almost perfectly to static load test values, was obtained with the AFNOR method, whereas the other predictions significantly underestimated the ultimate bearing capacity.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Related Concept Videos
Impact Strength of Concrete
Cable Subjected to a Distributed Load
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Cable: Problem Solving