Abstract:
Past historical earthquake events from neighbouring countries have been proven to be disastrous. Building in the aftermath of an earthquake may reduce structural reliability, posing risk upon re-occupation of the building. Shock absorber viscous dampers were installed on a specific structure storey that could reduce the spectral acceleration and storey-drift caused by an earthquake. The research object is a low-rise, three-storey, reinforced concrete (RC) structure. This study aims to identify the dynamic response of the scaled RC structure with and without attached dampers and performs structural reliability of the tested model under the excitation of Peak Ground Acceleration (PGA) of 0.1 g to 1.0 g with a unidirectional shaking table. APIDO viscous dampers were installed parallel to the movement direction of the dynamic load test. The findings show the scaled model with attached viscous dampers reduces spectral acceleration and storey drift by 9.66% and 4.85%, respectively. Findings also show the change of the structural behaviour from single curvature to double curvature due to the increase in seismic structural resistance by viscous dampers. The breakthrough of this research shows that structural reliability analysis performed by the Weibull distribution function has a base shear capacity increment of 1.29% and 6.90% in seismic performance level Life Safety (LS) and Collapse Prevention (CP), respectively. The novelty of this case study building with dampers managed to increase the building's base shear and roof shear capacity by 6.90% and 16% compared to the building without dampers under dynamic load excitation.
More Related Videos
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Applications of Stress
The...
Stability of structures
Statically Indeterminate Problem Solving
Indeterminate Structure
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...