Related Experiment Video
Updated: Sep 27, 2025

Collecting Sleep, Circadian, Fatigue, and Performance Data in Complex Operational Environments
Published on: August 8, 2019
Inter-Comparison of UT1-UTC from 24-Hour, Intensives, and VGOS Sessions during CONT17
Shrishail Raut1,2, Robert Heinkelmann1, Sadegh Modiri3
1GFZ German Research Centre for Geosciences, 14473 Potsdam, Germany.
Abstract:
This work focuses on the assessment of UT1-UTC estimates from various types of sessions during the CONT17 campaign. We chose the CONT17 campaign as it provides 15 days of continuous, high-quality VLBI data from two legacy networks (S/X band), i.e., Legacy-1 (IVS) and Legacy-2 (VLBA) (having different network geometry and are non-overlapping), two types of Intensive sessions, i.e., IVS and Russian Intensives, and five days of new-generation, broadband VGOS sessions. This work also investigates different approaches to optimally compare dUT1 from Intensives with respect to the 24 h sessions given the different parameterization adopted for analyzing Intensives and different session lengths. One approach includes the estimation of dUT1 from pseudo Intensives, which are created from the 24 h sessions having their epochs synchronized with respect to the Intensive sessions. Besides, we assessed the quality of the dUT1 estimated from VGOS sessions at daily and sub-daily resolution. The study suggests that a different approach should be adopted when comparing the dUT1 from the Intensives, i.e., comparison of dUT1 value at the mean epoch of an Intensive session. The initial results regarding the VGOS sessions show that the dUT1 estimated from VGOS shows good agreement with the legacy network despite featuring fewer observations and stations. In the case of sub-daily dUT1 from VGOS sessions, we found that estimating dUT1 with 6 h resolution is superior to other sub-daily resolutions. Moreover, we introduced a new concept of sub-daily dUT1-tie to improve the estimation of dUT1 from the Intensive sessions. We observed an improvement of up to 20% with respect to the dUT1 from the 24 h sessions.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
06:36Author Spotlight: Insights into the Analysis of Human Interaction with 3D Virtual Objects
Published on: October 18, 2024
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Types of Global Positioning System Surveys
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...