Related Experiment Video
Updated: Sep 27, 2025

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Electropolymerized, Molecularly Imprinted Polymer on a Screen-Printed Electrode-A Simple, Fast, and Disposable
Isabel Seguro1, Patrícia Rebelo1, João G Pacheco1
1REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida 431, 4200-072 Porto, Portugal.
Abstract:
In recent years, analytical chemistry has been facing new challenges, particularly in developing low-cost, green, and easy-to-reproduce methods. In this work, a simple, reproducible, and low-cost electrochemical (voltammetric) molecularly imprinted polymer (MIP) sensor was designed specifically for the detection of trazodone (TZD). Trazodone (TZD) is an antidepressant drug consumed worldwide since the 1970s. By combining electropolymerization (surface imprinting) with screen-printed electrodes (SPCEs), the sensor is easy to prepare, is environmentally friendly (uses small amounts of reagents), and can be used for in situ analysis through integration with small, portable devices. The MIP was obtained using cyclic voltammetry (CV), using 4-aminobenzoic acid (4-ABA) as the functional monomer in the presence of TZF molecules in 0.1 M HCl. Non-imprinted control was also constructed in the absence of TZD. Both polymers were characterized using CV, and TZD detection was performed with DPV using the oxidation of TZD. The polymerization conditions were studied and optimized. Comparing the TZD signal for MIP/SPCE and NIP/SPCE, an imprinting factor of 71 was estimated, indicating successful imprinting of the TZD molecules within the polymeric matrix. The analytical response was linear in the range of 5-80 µM, and an LOD of 1.6 µM was estimated. Selectivity was evaluated by testing the sensor for molecules with a similar structure to TZD, and the ability of MIP/SPCE to selectively bind to TZD was proven. The sensor was applied to spiked tap water samples and human serum with good recoveries and allowed for a fast analysis (around 30 min).
More Related Videos
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
07:51Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Potentiometry: Membrane Electrodes