Related Experiment Video
Updated: Sep 27, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Phase One of a Global Evaluation of Suction-Based Airway Clearance Devices in Foreign Body Airway Obstructions: A
Cody L Dunne1,2, Selena Osman3, Kayla Viguers4
1Department of Emergency Medicine, University of Calgary, Calgary, AB T2N2T9, Canada.
Abstract:
Background: Choking is a prevalent source of injury and mortality worldwide. Traditional choking interventions, including abdominal thrusts and back blows, have remained the standard of care for decades despite limited published data. Suction-based airway clearance devices (ACDs) are becoming increasingly popular and there is an urgent need to evaluate their role in choking intervention. The aim of this study was to describe the effectiveness (i.e., resolution of choking symptoms) and safety (i.e., adverse events) of identified airway clearance devices interventions to date. Methods: This retrospective descriptive analysis included any individual who self-identified to manufacturers as having used an ACD as a choking intervention prior to 1 July 2021. Records were included if they contained three clinical variables (patient’s age, type of foreign body, and resolution of choking symptoms). Researchers performed data extraction using a standardized form which included patient, situational, and outcome variables. Results: The analysis included 124 non-invasive (LifeVac©) and 61 minimally invasive (Dechoker©) ACD interventions. Median patient age was 40 (LifeVac©, 2−80) and 73 (Dechoker©, 5−84) with extremes of age being most common [<5 years: LifeVac© 37.1%, Dechoker© 23.0%; 80+ years: 27.4%, 37.7%]. Food was the most frequent foreign body (LifeVac© 84.7%, Dechoker© 91.8%). Abdominal thrusts (LifeVac© 37.9%, Dechoker© 31.1%) and back blows (LifeVac© 39.5%, Dechoker© 41.0%) were often co-interventions. Resolution of choking symptoms occurred following use of the ACD in 123 (LifeVac©) and 60 (Dechoker©) cases. Three adverse events (1.6%) were reported: disconnection of bellows/mask during intervention (LifeVac©), a lip laceration (Dechoker©), and an avulsed tooth (Dechoker©). Conclusion: Initial available data has shown ACDs to be promising in the treatment of choking. However, limitations in data collection methods and quality exist. The second phase of this evaluation will be an industry independent, prospective assessment in order to improve data quality, and inform future choking intervention algorithms.
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...