Related Experiment Video
Updated: Sep 27, 2025

A Neonatal Imaging Model of Gram-Negative Bacterial Sepsis
Published on: August 12, 2020
Does the delivery mode affect post-birth neonatal serum C-reactive protein levels? A causal effect analysis
Tal Kozlovski1,2, Sivan Yochpaz2,3, Ido Shachar4
1Laboratory for Early Markers of Neurodegeneration (LEMON), Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Delivery mode impacts neonatal C-reactive protein (CRP) levels. Elective caesarean delivery is associated with 50% lower CRP levels in newborns compared to vaginal delivery within 6-8 hours of birth.
Area of Science:
- Neonatal Medicine
- Biochemistry
- Obstetrics
Background:
- Neonatal serum C-reactive protein (CRP) is a key biomarker for inflammation and infection.
- Understanding factors influencing early neonatal CRP levels is crucial for diagnosing conditions like early-onset neonatal sepsis (EONS).
- Delivery mode is a potential confounding factor in interpreting neonatal CRP levels.
Purpose of the Study:
- To investigate the causal effect of delivery mode on neonatal serum CRP levels.
- To quantify the magnitude of this effect if it exists.
- To inform clinical interpretation of CRP in neonates based on delivery method.
Main Methods:
- Retrospective analysis of 440 neonates' laboratory records.
- Utilized statistical tools combining classical and machine-learning methods for causal inference.
- Conducted sensitivity analysis to assess the impact of unobserved bias.
Main Results:
- Neonates born via elective caesarean delivery had 50% lower serum CRP levels compared to those born via vaginal delivery (P=0.030).
- No significant difference in CRP levels was observed between urgent caesarean delivery and vaginal delivery (P=0.887).
- Results were robust to unobserved bias and consistent when analyzing samples collected later (12-24h).
Conclusions:
- Elective caesarean delivery is associated with significantly lower neonatal CRP concentrations in the first 6-8 hours of life compared to vaginal delivery.
- Delivery mode should be considered when interpreting neonatal CRP levels, particularly for EONS detection.
- Further research incorporating delivery mode is recommended for improved EONS diagnostic strategies.
More Related Videos
07:36Modeling Encephalopathy of Prematurity Using Prenatal Hypoxia-ischemia with Intra-amniotic Lipopolysaccharide in Rats
Published on: November 20, 2015
08:50A Murine Model of Fetal Exposure to Maternal Inflammation to Study the Effects of Acute Chorioamnionitis on Newborn Intestinal Development
Published on: June 24, 2020
Related Concept Videos
Rh Blood Group
Regression Toward the Mean
Transcytosis of IgG
IgG molecules from a mother undergo transcytosis starting around 13 weeks of gestation. The amount of IgG transferred and entering the fetal blood circulation increases with...