[Discussion on Testing and Standard of Blood Pressure Sensor at the Tip of Catheter]
Jia Tian1, Shuo Jiang1, Li Fu1
1Shandong Institute of Medical Device and Pharmaceutical Packaging Inspection, Jinan, 250101.
Abstract:
With the implementation of the new policy for coronary stent centralized volume purchasing in China, the blood pressure sensor at the tip of the catheter, as one of the essential medical instruments for the diagnosis and treatment of coronary artery disease, will meet the new development opportunity of the industry, a number of medical device companies will actively participate in the development and registration of the catheter tip blood pressure sensor. As an invasive blood pressure sensor, the catheter tip blood pressure sensor should meet the current effective industry standard YY 0781-2010, however, there are many problems when using YY 0781-2010 as a blood pressure sensor because of the difference of product structure and working mode. In this paper, the problems about "Operation Manual", "electrical performance" and "safety requirement" in the course of carrying out YY 0781- 2010 with the blood pressure sensor on the tip of catheter are discussed and analyzed in detail, hope to provide some inspiration for more research and development enterprises of blood pressure sensors on the tip of catheters and inspectors of medical device testing institutions, also hope to be able to contribute to the high-quality development of blood pressure sensor industry at the tip of the Catheter.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: