Devices measuring transepidermal water loss: A systematic review of measurement properties
Tanja Klotz1,2, Abdullah Ibrahim3, Guy Maddern4
1Adelaide Medical School, The University of Adelaide, Adelaide, Australia.
Objective:
The objective of this review is to examine the reliability and measurement error of devices that measure transepidermal water loss (TEWL).
Introduction:
TEWL is a physiological property of skin which increases when the epidermis is damaged. It is, therefore, a commonly utilised measure of skin barrier integrity. Devices measuring TEWL are available as open, semi-open or closed chamber. Studies of reliability examine the consistency of measurement, and/or responsiveness whereas measurement error scores in absolute terms the amount of error due to sources of variation.
Inclusion Criteria:
Studies examining the reliability and/or measurement error of TEWL measurement devices were included. Studies that only report on measurement of TEWL outcomes without examination of reliability and/or measurement error were excluded.
Methods:
The search strategy aimed to locate published and unpublished studies. Databases searched included PubMed, Embase, CINAHL and Web of Science, utilising identified keywords and limited to studies in English. Grey literature sources were searched to identify any unpublished documents. Study selection using the inclusion criteria was then assessed by two reviewers for methodological quality utilising the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) risk of bias tool to assess the reliability and measurement error of outcome measurement instruments.
Results:
A total of 22 devices were examined in the 38 included studies. The quality of study design was on average rated as 'Adequate' however reliability and measurement error statistical methods were on average rated as 'Doubtful'.
Discussion And Conclusion:
TEWL measurement devices were found to demonstrate good reliability and frequently correlated with other devices. However, measurement error was highly variable but improves under in vitro conditions. Future research should consider risk of bias factors when designing studies.
Related Concept Videos
Adaptations that Reduce Water Loss
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...