Related Experiment Video
Updated: Sep 27, 2025

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
The simpler the better: Highly sensitive 17α-ethinylestradiol sensor based on an unmodified carbon paper transducer
Álvaro Torrinha1, Pedro Carneiro1, Diana Dias1
1REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, 431, 4249-015 Porto, Portugal.
Abstract:
The remarkable features of a carbon fiber paper sensor (CP) were employed for detection of the estrogenic hormone 17α-ethinylestradiol (EE2), considered a contaminant of emerging concern due to its potential ecotoxicity and widespread in the aquatic ecosystems. In this work, an unpreceded CP pre-treatment study was conducted with the (Il)-hexacyanoferrate(III) ion pair, however a bare sensor without pre-treatment revealed higher efficiency on the oxidation of EE2 compared to a chemical and electrochemical pre-treated CP and a gold nanoparticles modified CP, being thus selected for EE2 determinations. The analytical conditions were thoroughly optimized in terms of electrolyte pH (pH 7), differential pulse voltammetry parameters (modulation time 0.003 s, amplitude 0.09 V, interval time 0.1 s and step potential 0.01 V), and analyte preconcentration potential (0.4 V) and time (180 s). The hormone can be determined by the CP in a wide linear range from 0.1 to 1000 nM, achieving a detection limit of 0.14 ± 0.005 nM and an outstanding sensitivity of 1636 ± 232 μA μM-1 cm-2 in the lowest linear zone (0.1-1 nM). The sensor was validated in river water and fish reaching good recoveries (91.2 ± 4.6 to 109.0 ± 7.1%), reproducibility and repeatability. Moreover, the sensor showed high selectivity to EE2 in the presence of several potential interfering compounds and frequently prescribed drugs, though it could not discriminate the similar hormone, 17β-estradiol, being the total concentration obtained in this case. CP-based sensors emerge as efficient electroanalytical tools, suggesting that modification of the surface may not always be beneficial in terms of sensitivity.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
08:22Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018