Imaging of the Microstructural Failure Mechanism in the Human Hip
Published on: September 29, 2023
Finite element analysis of a hybrid corrugated hip implant for stability and loading during gait phases
Vivek Gupta1, Arnab Chanda1,2
1Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India.
Abstract:
Implants used in total hip replacements (THR) exhibit high failure rates and up to a decade of operational life. These surgical failures could be mainly attributed to the improper positioning, post-surgical stability and loading, of the implants during different phases of the gait. Typically, revised surgeries are suggested within a few years of hip implantation, which requires multiple femoral drilling operations to remove an existing implant, and to install a new implant. The pain and trauma associated with such procedures are also challenging with the existing hip implants. In this work, we designed a novel corrugated hip implant with innovative dimensioning as per ASTM standards, and grooves for directed insertion and removal (using a single femoral drilling and positioning operation). Biocompatible titanium alloy (Ti6Al4V) was chosen as the implant material, and the novel implant was placed into a femur model through a virtual surgery to study its stability and loading during a dynamic gait cycle. A detailed mesh convergence study was conducted to select a computationally accurate finite element (FE) mesh. Tight fit and frictional fit attachment conditions were simulated, and the gait induced displacements and stresses on the implant, cortical and cancellous bone sections were characterized. During walking, the implant encountered the maximum von-Mises stress of 254.97 MPa at the femoral head. The analyses indicated low micro-motions (i.e., approximately 7μm) between the femur and implant, low stresses at the implant and bone within elastic limits, and uniform stress distribution, which unlike existing hip implants, would be indispensable for bone growth and implant stability enhancement, and also for reducing implant wear.
Related Concept Videos
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
Eccentric Axial Loading in a Plane of Symmetry
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...