Related Experiment Video
Updated: Sep 27, 2025

Visual Detection of Multiple Nucleic Acids in a Capillary Array
Published on: November 15, 2017
Loop-mediated isothermal amplification-based nucleic acid lateral flow assay for the specific and multiplex detection
Seokhwan Kim1, Jung Ho Kim1, Seokjoon Kim1
1Department of Biological Engineering, College of Engineering, Konkuk University, Seoul, 05029, Republic of Korea.
Abstract:
In this study, a loop-mediated isothermal amplification-based nucleic acid lateral flow assay (LAMP-NALFA) system was developed for the specific and multiplex detection of genetic markers at a low cost. In principle, the LAMP reaction was optimized to generate a single-stranded sequence in the LAMP product, which was designed to serve as a barcode sequence and to specifically bind to the DNA capture on a NALFA strip. As a target genetic marker, the Salmonella enterotoxin (stn) gene was chosen and determined down to 9 aM (∼5.44 copies/μL). Importantly, the proposed system clearly discriminated the specific target amplification products from non-specific amplification products resulting from primers or non-target nucleic acids, proving the high selectivity of the LAMP-NALFA system. Furthermore, the practical applicability of the system was demonstrated by detecting Salmonella bacteria in Luria-Bertani medium, drinking water, and eggshells, with a limit of detection of 1.6 CFU. Finally, two different bacteria (Salmonella and Staphylococcus) were simultaneously determined by the multiplex LAMP-NALFA system. It is expected that the LAMP-NALFA system could be used in a point-of-care setting for the detection of bacteria or viruses, consequently improving both individual and public health.