Related Experiment Video
Updated: Sep 27, 2025

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Changes in the cuff pressure in neonates in the absence of nitrous oxide
Ayten Saracoglu1, Kemal T Saracoglu2, Huseyin Canaz3
1Department of Anesthesiology and Intensive Care, Marmara University School of Medicine, Turkey.
Background:
Changes in the pressure of cuffed neonatal size tracheal tubes (TT) during anaesthesia without nitrous oxide are not well described. We determined whether the cuff pressure changes over time in neonates under general anaesthesia without nitrous oxide.
Methods:
The airways of thirty neonates were secured with a high volume low pressure cuffed TT for meningocele surgery. The cuff was manually inflated until there was no audible leak and maintained at 10-15 cm H2O throughout by monitoring the pressure continuously with both a manometer and a pressure transducer. At baseline, the cuff pressure was assessed in the supine and then prone positions. During surgery, if the pressure exceeded 15 cm H2O, the cuff was deflated to < 15 cm H2O and if it was < 10 cm H2O, the cuff was inflated to 10-15 cm H2O. The time interval between corrections and the number of corrections were recorded.
Results:
The cuff pressures in 18 neonates (60%) required correction during surgery. The cuff pressure exceeded 15 cm H2O in nine neonates (30%) and was corrected. The cuff pressures in 13 neonates were less than 10 cm H2O and required correction. The gender, weight, height, and duration of anaesthesia did not differ significantly between neonates who required correction of the cuff pressure and those who did not. Mean cuff pressures were similar at 15, 45, and 75 minutes of anaesthesia.
Conclusions:
In 60% of neonates undergoing surgery in the prone position under general anaesthesia without nitrous oxide, the cuff pressure exceeded 15 cm H2O. In such cases, cuff pressure should be monitored continuously throughout the surgery.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.