Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
Effect of Structural Fine-Tuning on Chelate Stability and Liver Uptake of Anionic MRI Contrast Agents
Ah Rum Baek1, Hee-Kyung Kim2, Soyeon Kim3
1Institute of Biomedical Engineering Research, Kyungpook National University, 41405 Daegu, Korea.
Abstract:
The purpose of this study is to assess the physicochemical properties and MRI diagnostic efficacy of two newly synthesized 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-type Gd chelates, Gd-SucL and Gd-GluL, with an asymmetric α-substituted pendant arm as potential hepatocyte-specific magnetic resonance imaging contrast agents (MRI CAs). Our findings show that fine conformational changes in the chelating arm affect the in vivo pharmacokinetic behavior of the MRI CA, and that a six-membered chelating substituent of Gd-SucL is more advantageous in this system to avoid unwanted interactions with endogenous species. Gd-SucL exhibited a general DOTA-like chelate stability trend, indicating that all chelating arms retain coordination bonding. Finally, the in vivo diagnostic efficacy of highly stable Gd-SucL as a potential hepatocyte-specific MRI CA was evaluated using T1-weighted MR imaging on an orthotopic hepatocarcinoma model.
More Related Videos
Related Concept Videos
Complexation Equilibria: The Chelate Effect
EDTA: Chemistry and Properties
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
EDTA: Auxiliary Complexing Reagents
Extraction: Advanced Methods
Magnetic Resonance Imaging