Comprehensive characterization of polycyclic aromatic hydrocarbon emissions from heavy-duty diesel vehicles utilizing
Ting Chen1, Xuan Zheng1, Xiao He1
1College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China.
Abstract:
Comprehensive characterization of diesel vehicle emitted polycyclic aromatic hydrocarbon (PAH) emissions is yet to achieve due to the limitation of analytical methods. Therefore, we herein developed a two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-ToF-MS) method and quantified the total PAHs from diesel vehicles based on their characteristic fragments and mass spectral patterns. Overall, the emission factors (EFs) of total PAHs (gas + particle) are observed to range from 4.1 ± 2.5 mg km-1 to 51.4 ± 22.2 mg km-1 under cold-start and hot-start conditions for one China IV and two China VI heavy-duty diesel vehicles (HDDVs), of which the un-speciated PAHs account for more than 97%. Gaseous PAHs (g-PAHs) are dominated by three-ring PAHs, whereas particulate PAHs (p-PAHs) are dominated by two-ring PAHs. The total PAHs partition significantly into the gas phase for whole fleets and cycles, except that five-ring PAHs partition almost completely into the particle phase. The aftertreatment technologies (e.g., diesel particulate filter, DPF) significantly reduce the total PAH emissions by 49.8 ± 33.2%. The minimum toxic equivalency factors (TEFs) are deployed to estimate the toxicity of the total PAHs. Much higher toxicity is obtained than those in previous studies, indicating that the PAH toxicity of diesel vehicle emissions might be largely underestimated.
More Related Videos
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...