Related Experiment Video
Updated: Sep 27, 2025

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
Published on: April 25, 2025
Industrial water network vulnerability analysis using dynamic inoperability input-output model
Yanmei Zhang1, Zhiwei Li2, Kathleen B Aviso3
1School of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China.
Abstract:
Industrial parks provide opportunities for Process Integration among different enterprises. Inter-Plant Water Network Integration is an effective strategy for water conservation. However, increased interplant linkages can make the entire system vulnerable to cascading failures in case of loss of water flow in some plants. The potential indirect impact of water shortages on such integrated systems may not be evident without the use of appropriate models. This work defines inoperability as the fractional loss of water flow relative to normal operations. A comparison between the applicability of demand-driven versus supply-driven Inoperability Input-output Model (IIM) is conducted. Then, a Vulnerability Assessment Framework which integrates vulnerability indicators into the Dynamic Input-Output Model (DIIM) is developed to analyse failure propagation in water networks in an industrial park. The DIIM is then applied to simulate the cascading effects of disturbances. From a time perspective, the vulnerabilities of the industrial parks With Integrated Optimal Water Network (WWN) and Without Integrated Optimal Water Network (WOWN) are assessed considering robustness, adaptability, and recoverability as the indicators. The results indicate that supply-driven IIM is more suitable for cascading failure analysis of water networks. The average inoperability at 16% from supply-driven IIM is higher than that from demand-driven IIM. In the freshwater disturbance scenario, the dependence of the plant on freshwater is proportional to the rate of inoperability change, the time to reach a new equilibrium. In this study, the robustness of WWN is about fivefold that of WOWN, but the recovery rate is only one-sixth of the latter. This work can help identify system vulnerabilities and provide a scientific insight for the development of park-wide water management strategies.
Related Concept Videos
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Typical Model Studies
Design Example: Creating a Hydraulic Model of a Dam Spillway
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Regulation of Water Output
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...

