Related Experiment Video
Updated: Sep 27, 2025

Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo
Published on: August 4, 2018
In Vivo Temperature Rise Measurements of Rabbit Liver and Femur Bone Surface Exposed to an Acoustic Radiation Force
Naotaka Nitta1, Yasunao Ishiguro2, Hideki Sasanuma2
1Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan.
Abstract:
Acoustic radiation force impulse (ARFI) imaging and shear wave elastography use a "push pulse." The push pulse, which is referenced as an ARFI in this study, has a longer duration than that of conventional diagnostic pulses (several microseconds). Therefore, there are concerns regarding thermal safety in vivo. However, few in vivo studies have been conducted using living animals. In this study, to suggest a concept for deciding an ARFI output and cooling time while considering thermal safety, the liver (with and without an ultrasound contrast agent) and femur bone surface of living rabbits were exposed to an ARFI, and the maximum temperature rise, temperature rise for 5-min duration, and cooling time were measured via a thermocouple. While testing within the regulation limits of diagnostic ultrasound outputs, a maximum temperature rise on the femur bone surface exceeded the allowable temperature rise (1.5°C) in the British Medical Ultrasound Society (BMUS) statement. However, using the linear relationships between the pulse intensity integral (PII) of a single pulse and the above three temperature parameters, PII may be determined so that the maximum temperature rise is within the allowable temperature rise in the BMUS statement. The cooling time can be estimated from the PII.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

