Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead
Keshavamurthy Ganapathy Bhat1, Vivek Singh Guleria1, Manish Singla1
1Department of Cardiology, Army Hospital Research & Referral, New Delhi, India.
Objective:
RADPAD is a lead-free sterile drape that reduces scattered radiation during fluoroscopic procedures. We aimed to study the effect of using RADPAD on primary operator (PO) and secondary operator (SO) during coronary angiography (CAG) as well as percutaneous coronary intervention (PCI).
Methods:
137 patients undergoing elective CAG and PCIwere randomized in a 1:1 pattern with or without the RADPAD. The ratio of PO received dose in mrem to total Air Kerma (AK) in mGy, Dose Area Product (DAP) in mGycm2 and Cine Adjusted Screening Time (CAST) in minute, at the end of the procedure with or without RADPAD were measured and designated as dose relative to AK, DAP and CAST. The exposure ratios were compared for both cohorts.
Results:
There was no significant difference in CAST, DAP and AK between the two patient cohorts. PO radiation dose relative to CAST was 0.15 ± 0.18 mrem/min for RADPAD cohort and 0.43 ± 0.31 mrem/min for No RADPAD cohort (p < 0.00001). PO dose relative to DAP was 0.00042 ± 0.00049 mrem/mGycm2 for RADPAD cohort and 0.0011 ± 0.0013 mrem/mGycm2 for No RADPAD cohort (p = 0.000014). PO dose relative to AK was 0.0030 ± 0.0037 mrem/mGy for RADPAD cohort and 0.0071 ± 0.0049 mrem/mGy for No RADPAD cohort (p < 0.00001). All PO doses relative to CAST, DAP and AK were significantly reduced in the RADPAD cohort compared to the No RADPAD cohort. Similar findings were observed for the SO also.
Conclusion:
RADPAD significantly reduces radiation exposure to both PO and SO during CAG and PCI.
More Related Videos
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization III: Left Heart Catheterization
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...