Evaluation of moyamoya disease in CT angiography using ultra-high-resolution computed tomography: Application of deep
Yasuhiro Fukushima1, Yasutaka Fushimi2, Takeshi Funaki3
1Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawaharacho, Shogoin, Sakyo-ku Kyoto 606-8507, Japan.
Purpose:
The aim of this study was to examine the evaluation of ultra-high-resolution computed tomography angiography (UHR CTA) images in moyamoya disease (MMD) reconstructed with hybrid iterative reconstruction (Hybrid-IR), model-based iterative reconstruction (MBIR), and deep learning reconstruction (DLR).
Methods:
This retrospective study with institutional review board approval included patients with clinically suspected MMD who underwent UHR CTA between January 2018 and July 2020. CTA images were reconstructed with three reconstruction methods. Qualitative visualization was evaluated in comparison with digital subtraction angiography. Quantitative evaluation included assessment of edge sharpness, full width at half maximum (FWHM), vessel contrast, and tissue signal-to-noise ratio (SNRtissue). One-way analysis of variance was used to analyze differences. In addition, reconstruction time were assessed.
Results:
Qualitative evaluation of CTA for 33 sides did not differ significantly between reconstruction methods. In quantitative evaluation for 54 patients, edge sharpness for right and left cortical segments of the middle cerebral artery was significantly higher for Hybrid-IR than for other reconstructions. No significant difference was seen between MBIR and DLR. Edge sharpness for STA-MCA bypass was significantly higher for Hybrid-IR than for MBIR, but no significant difference was seen between Hybrid-IR and DLR. FWHM for STA-MCA showed no significant difference between the three reconstruction methods. DLR displayed the highest SNRtissue. The time required for reconstruction was 40 s for Hybrid-IR, 2580 s for MBIR, and 180 s for DLR.
Conclusion:
UHR CTA with DLR adequately visualized vessels in patients with MMD within a clinically feasible reconstruction time.
More Related Videos
05:12Induction and Micro-CT Imaging of Cerebral Cavernous Malformations in Mouse Model
Published on: September 4, 2017
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI