Related Experiment Video
Updated: Sep 26, 2025

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
Published on: August 17, 2015
Rates and Reasons of Laboratory Sample Rejection due to Pre-analytical Errors in Clinical Settings
Elham Jafari1, Reza Malekpour Afshar1, Razieh Aminzade1
1Pathology and Stem Cells Research Center, Department of Pathology, Kerman University of Medical Sciences, Kerman, Iran.
Background:
Laboratory analysis errors in procedure or interpretation may be seen during the process of completing physician test orders. They may also result in rejection of the requests due to some applicability reasons. Hence, this study was carried out to determine the rate and reasons for such rejections in clinical settings.
Methods:
This cross-sectional comparative study was performed on 104008 laboratory tests in a one-year period in terms of the percentage and type of errors that occurred in Shahid Bahonar Hospital in Kerman, Iran, in 2018. The types of studied errors included hemolysis, sample clotting, insufficient sample size, and mistakes in labels or absence of labels on the sample.
Results:
In this study, 104008 laboratory tests were performed, with 2299 (2.21%) sample rejections, 456 (32.31%) complete blood count (CBC) sample clotting; 417 (29.38 %) hemolysis; and 150 (17.47 %) inadequate sample volume as the majority of errors. There was no statistically significant relationship between pre-analysis errors and clinical aspects (P=0.124).
Conclusion:
According to the results, it may be concluded that considering the high prevalence of laboratory errors in comparison with the majority of other studies, continuous training courses and determination of the causes of these errors are crucial to attaining better function and basic knowledge.
More Related Videos
Related Concept Videos
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Errors occurring during blood pressure monitoring
Several factors...
Data Validation
Key parameters for method validation include:
Random and Systematic Errors
Sampling Methods: Overview
In analytical chemistry, the choice of...