Trocar-assisted flanged transconjunctival intrascleral sutureless intraocular lens fixation
Sherif A GamalElDin1, Malak I ElShazly2, Marwa M Salama2
1Professor of Ophthalmology, 63527Cairo University, Cairo, Egypt.
Purpose:
To study the safety and efficacy of 25-gauge trocar-assisted flanged intrascleral sutureless IOL fixation in patients with insufficient posterior capsular support.
Methods:
Five aphakic eyes with capsular insufficiency were included in this prospective interventional case series study, at Dar El Oyoun Hospital, Cairo, Egypt. Twenty five-gauge trocar-assisted flanged intrascleral sutureless technique was used for IOL fixation, in which retinal microforceps were used to capture and externalize both haptics through a scleral tunnel. CDVA, IOP measurements and IOL centralization were reported pre- and one day, one & 3 months postoperatively. Any intra- or postoperative complications were recorded.
Results:
The mean LogMAR CDVA had significantly improved one day, 1 & 3 months postoperatively (0.74 ± 0.1, 0.42 ± 0.07 and 0.26 ± 0.08 respectively, p < 0.001) compared to the preoperative value (1.7 ± 0.17). The mean IOP showed no significant changes along the follow-up period (16.9 ± 0.1; 16.2 ± 1.1; 16.3 ± 0.9 mmHg, p = 0.68, 0.58, 0.89) respectively at 1st day, 1 & 3 months postoperatively) compared to the preoperative measurement (16.4 ± 1.8 mmHg). The IOL was found to be centralized in all cases. No intra- or postoperative complications were encountered.
Conclusion:
25-gauge trocar-assisted flanged intrascleral sutureless IOL fixation is found to be a reliable and effective technique that overcomes Yamane technique's challenges for IOL fixation in cases with posterior capsular insufficiency.