Related Experiment Video
Updated: Sep 26, 2025

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Robotic-assisted beating heart surgery provides precise repair of periprosthetic mitral valvular leak
Muharrem Kocyigit1, Ahmet Umit Gullu1, Sahin Senay1
1Department of Cardiovascular Surgery, Acıbadem Mehmet Ali Aydınlar University School of Medicine, Istanbul, Turkey.
Abstract:
The prosthetic paravalvular leak is a rare but important complication following mitral valve replacement. Determining the location of the leak is almost always dependent on perioperative transoesophageal echocardiography and the considerable expertise of echo operators. Acoustic shadowing due to the prosthetic valve may create another important difficulty. In this report, we present a case with a paravalvular leak diagnosed 1 year after mitral valve replacement. Beating heart surgery and robotic 3D/high-resolution camera provided to localize the direct location of leak coherent with perioperative echocardiography and precise repair. The robotic approach prevented the potential complications of aortic cross-clamp and resternotomy.
More Related Videos
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management