Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

342
A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
342
Development of Analytical Methods01:21

Development of Analytical Methods

776
An analytical methodology can be divided into four sequential steps: technique, method, procedure, and protocol. A technique is a scientific principle that rationalizes a specific phenomenon through chemical measurements. Adapting a technique for analyzing a sample of interest is termed a method. The procedure outlines the directions for performing the analysis via an analytical method. The protocol is the detailed guidelines on the procedure, which should be strictly followed to obtain the...
776
Sieve Analysis and Grading Curves01:19

Sieve Analysis and Grading Curves

562
Sieve analysis is a method used to determine the particle size distribution of aggregate materials. This process involves the following steps:
562
Data Validation01:15

Data Validation

278
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
278
Bode Plots01:26

Bode Plots

896
Bode plots are graphical tools that use logarithmic scales for frequency on the x-axis and gain in decibels on the y-axis. This logarithmic method allows a wide range of frequencies to be compactly displayed, enabling the analysis of component effects on circuit behavior across a broad frequency spectrum.
A network function represents the ratio of a system's output to its input, with the magnitude and phase angle derived from the complex network function. The decibel logarithmic gain is...
896
Bode Plots Construction01:24

Bode Plots Construction

830
The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
830

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

What are the correlates of laboratory productivity in clinical laboratories in the Asia Pacific region?

Clinical biochemistry·2026
Same author

An improved approach to modelling patient reclassification: HbA<sub>1c</sub> as an example.

Clinical chemistry and laboratory medicine·2026
Same author

Methodology and quality assurance practices in performing anti-extractable nuclear antigen (ENA) analysis: an EFLM report on an international survey.

Clinical chemistry and laboratory medicine·2026
Same author

The value of external quality assurance programs in identifying shifts in high-sensitivity troponin assays: a case for careful selection of low-level target concentrations.

Pathology·2026
Same author

An analysis of 10 years of synovial fluid crystal external quality assurance data.

Pathology·2026
Same author

Nationwide Survey on Knowledge, Attitudes, and Practices regarding Reference Interval Utilization in Clinical Laboratories in Nepal.

EJIFCC·2026
Same journal

Reference intervals for venous blood gas measurement in a healthy Chinese population.

Clinica chimica acta; international journal of clinical chemistry·2026
Same journal

Multiplex methylation marker analysis for ctDNA detection in liquid biopsies from anal cancer patients: an HPV-independent approach.

Clinica chimica acta; international journal of clinical chemistry·2026
Same journal

Development and validation of patient-based exponentially weighted moving average quality control models for three antipsychotic drugs and their metabolites by LC-MS/MS.

Clinica chimica acta; international journal of clinical chemistry·2026
Same journal

Comparing conventional correction formulas and machine learning-based prediction of ionized calcium.

Clinica chimica acta; international journal of clinical chemistry·2026
Same journal

Micro- and nanoplastics as emerging clinical analytes: analytical validation, interpretive uncertainty, and laboratory actionability in human specimens.

Clinica chimica acta; international journal of clinical chemistry·2026
Same journal

Performance of Free Light Chain reagents in the Dutch External Quality Assessment programme over the past 14 years.

Clinica chimica acta; international journal of clinical chemistry·2026
See all related articles

Related Experiment Video

Updated: Sep 26, 2025

Design and Optimization Strategies of a High-Performance Vented Box
14:23

Design and Optimization Strategies of a High-Performance Vented Box

Published on: June 9, 2023

1.2K

Improving Youden plots by including analytical performance specifications.

Wim Coucke1, Mohamed Rida Soumali1, Tony Badrick2

  • 1Sciensano - Quality of laboratories, J. Wytsmanstraat 14, 1040 Brussels, Belgium.

Clinica Chimica Acta; International Journal of Clinical Chemistry
|April 19, 2022
PubMed
Summary
This summary is machine-generated.

This study introduces a novel method for evaluating laboratory performance using Youden plots. The new approach enhances Youden plot analysis by incorporating acceptance areas to better assess variability and bias in medical laboratory science.

Keywords:
Analytical Performance SpecificationsExternal Quality AssessmentYouden plots

More Related Videos

Author Spotlight: Optimization of Processing Technology for Tiebangchui with Zanba Based on CRITIC Combined with Box-Behnken Response Surface Method
09:16

Author Spotlight: Optimization of Processing Technology for Tiebangchui with Zanba Based on CRITIC Combined with Box-Behnken Response Surface Method

Published on: May 12, 2023

1.2K
Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances
07:35

Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances

Published on: October 11, 2018

7.7K

Related Experiment Videos

Last Updated: Sep 26, 2025

Design and Optimization Strategies of a High-Performance Vented Box
14:23

Design and Optimization Strategies of a High-Performance Vented Box

Published on: June 9, 2023

1.2K
Author Spotlight: Optimization of Processing Technology for Tiebangchui with Zanba Based on CRITIC Combined with Box-Behnken Response Surface Method
09:16

Author Spotlight: Optimization of Processing Technology for Tiebangchui with Zanba Based on CRITIC Combined with Box-Behnken Response Surface Method

Published on: May 12, 2023

1.2K
Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances
07:35

Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances

Published on: October 11, 2018

7.7K

Area of Science:

  • Medical laboratory science
  • Analytical chemistry
  • Statistical quality control

Background:

  • Youden plots traditionally use scatter plots and elliptical confidence areas to compare laboratory results from EQA samples.
  • Current EQA (External Quality Assessment) practices often display total error limits on Youden plots, which have demonstrated weaknesses.
  • There is a need for improved methods to evaluate laboratory performance against established analytical performance specifications.

Purpose of the Study:

  • To identify the limitations of current total error limits displayed on Youden plots.
  • To propose and validate a new approach for defining acceptance areas on Youden plots.
  • To enhance the evaluation of individual laboratory results and measurement procedures.

Main Methods:

  • Developed a new method for creating acceptance areas on Youden plots, extending the classical approach.
  • Introduced two distinct acceptance areas: one for maximum allowed variability and another for variability plus bias.
  • Calculated elliptical acceptance areas using quantiles from the Chi-square and noncentral Chi-square distributions.

Main Results:

  • The proposed Youden plot method effectively evaluates individual laboratory results and measurement procedures.
  • Comparing the overlap of confidence areas and new acceptance areas provides a robust performance evaluation.
  • The new approach demonstrates superior control of type I errors compared to traditional rectangular limits.

Conclusions:

  • The enhanced Youden plot with tailored acceptance areas offers a more accurate and reliable method for assessing laboratory performance in medical diagnostics.
  • This novel approach improves the statistical validity of EQA assessments.
  • The method provides better control over statistical errors, leading to more trustworthy quality assessment in laboratory medicine.