Related Experiment Video
Updated: Sep 26, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
[Rapid determination of 30 volatile organic compounds in workplace air by gas chromatography]
1Inspection and Testing Department, Changxing Center for Disease Control and Prevention, Huzhou 313100, China.
Abstract:
Objective: To establish a method for rapid detection of DB-WAX capillary column and determination of the workplace air in 30 kinds of volatile organic pollutants. Methods: In August 2020, N-pentane, n-hexane, methylcyclohexane, octane, Acetone, ethyl acetate, butanone, benzene, 3-pentanone, trichloroethylene, tetrachloroethylene, toluene, butyl acetate, 2-hexanone, Isoamyl acetate, ethylbenzene, p-xylene, m-xylene, amyl acetate, o-xylene, chlorobenzene, styrene, cyclohexanone, P-chlorotoluene, bromobenzene, M-dichlorobenzene, p-dichlorobenzene, O-dichlorobenzene, o-Chlorotoluene, 1, 2 , 4-trichlorobenzene of 30 kinds of substances in air were collected by activated carbon tube. After analysis by carbon disulfide, the analytical solution was analyzed by DB-WAX column and determined by FID detector. Results: The above 30 kinds of volatile organic pollutants had good separation effect, the correlation coefficient of the standard curve was above 0.999, the relative standard deviation was 0.1%-3.2%, the desorption efficiency was 77.0%-117.1% , the lower limit of quantitation was 0.33-5.33 μg/ml, and the lowest quantitation concentration was 0.22-3.55 mg/m(3), the recoveries ranged was 95.4%-104.9%. Conclusion: The method can effectively separate and accurately determine 30 volatile organic compounds in these workplaces, and the method is simple and quick.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...