Related Experiment Video
Updated: Sep 26, 2025

Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Temperature dependence of diffusiophoresis via a novel microfluidic approach
Parth R Shah1, Huanshu Tan1, David Taylor1
1Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA 93106, USA. tsquires@ucsb.edu.
Abstract:
The temperature dependence of the diffusiophoretic mobility (DDP) is investigated experimentally and compared with theoretical predictions. These systematic measurements were made possible by a new microfluidic approach that enables truly steady state gradients to be imposed, and direct and repeatable measurements of diffusiophoretic migration to be made over hours-long time scales. Diffusiophoretic mobilities were measured for fluorescent, negatively charged polystyrene particles under NaCl gradients, at temperatures ranging from 20 °C to 70 °C. Measured DDP values were found to increase monotonically with temperature, and to agree, both qualitatively and relatively quantitatively, with theoretical predictions based on electrophoretically-measured zeta potentials. These results provide confidence that existing diffusiophoresis theories can accurately predict DP mobilities over a range of temperatures. More broadly, we anticipate our new microfluidic approach will facilitate and enable new tests of diffusiophoretic phenomena under a wide range of physical and chemical conditions.