Allowable room temperature excursions for refrigerated medications: A 20-year review
Lucas E Orth1,2, Amanda S Ellingson3, Sara F Azimi3
1Department of Clinical Pharmacy, University of Colorado Skaggs School of Pharmacy and Pharmaceutical Sciences, Aurora, CO.
Purpose:
The aim of this review was to build upon previous literature describing the maximum duration for which refrigerated medications can tolerate room temperature excursions while maintaining stability and potency.
Methods:
During a 12-month period ending in June 2021, the prescribing information and published monographs from multiple pharmacy compendia were reviewed for all medications and biologic products approved by the US Food and Drug Administration (FDA) for human use since January 2000. Products that were subsequently withdrawn from the US market were excluded. When temperature excursion data was unavailable in published form, product manufacturers were surveyed via telephone and/or email. Acceptable storage information for all products for which storage is recommended at temperatures below room temperature (20-25 °C [68-77 °F]) was compiled and arranged in tabular format.
Results:
Of the 705 products or formulations approved by FDA during the predefined time period, 246 were identified as requiring storage at temperatures below room temperature. After review of available prescribing information and manufacturer communications, if applicable, acceptable periods of excursion to temperatures at room temperature or higher were identified for 214 products (87%).
Conclusion:
Information related to acceptable periods of room temperature excursion was compiled for a total of 214 products approved for US distribution since 2000. The included tables may increase patient safety and decrease medication loss or related expenditures.
More Related Videos
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Physical Methods for Controlling Microbial Growth: Temperature
Increased Body Temperature
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Methods of reducing fever
Pharmacological Methods of Reducing Fever: