Related Experiment Video
Updated: Sep 26, 2025

Structural Design and Manufacturing of a Cruiser Class Solar Vehicle
Published on: January 30, 2019
Seismic Performance of F3D Free-Form Structures Using Small-Scale Shaking Table Tests
Min Jae Park1, Gain Cheon1, Robel Wondimu Alemayehu1
1School of Civil, Environmental and Architectural Engineering, Korea University, Seoul 02841, Korea.
Abstract:
In recent years, studies that can maximize irregularity have increased as technological constraints weaken owing to the development of construction technology and the increase in demand for free-form structures. Considering this, free-form structures have been constructed using various materials. Concrete is considered most suitable for realizing an atypical shape because it is highly economical and can be assembled in a free form. However, not many studies have evaluated the structural performance of free-form concrete structures using free-form formwork 3D printer (F3D) technology, a 3D printing technology. Free-form structures must be designed to secure structural stability under both dead and live loads, as well as natural hazards such as wind, snow, and earthquakes. Therefore, in this study, we tested a free-form structure constructed by F3D printing using small-scale models that satisfy the similitude law with shaking tables. Furthermore, a finite element analysis was conducted to validate the small-scale tests. Lastly, the seismic performance of free-form concrete structures was evaluated based on the test and analysis results.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
11:25A Millimeter Scale Flexural Testing System for Measuring the Mechanical Properties of Marine Sponge Spicules
Published on: October 11, 2017
Related Concept Videos
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Indeterminate Structure
Non-destructive Tests for Concrete Strength
Method of Sections
Shear and Bending Moment Diagram: Problem Solving
Draw a Free-Body Diagram: Start by drawing a free-body diagram of the entire beam, including the concentrated loads, distributed load, and reaction...