Flexural Performance of Cement-Treated Sand Reinforced with Geogrids for Use as Sub-Bases of Pavement and Railway Structures
Related Experiment Video
Updated: Sep 26, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Supphanut Chuenjaidee1, Pitthaya Jamsawang2, Pornkasem Jongpradist3
1Department of Civil Engineering, King Mongkut's University of Technology North Bangkok, Bangkok 10800, Thailand.
Abstract:
Cement-treated sand (CTS) exhibits undesirable brittle behavior after the applied stress reaches its peak strength. This research investigates the flexural behavior of CTS that is reinforced with uniaxial geogrid (CTSG). A total of 6% cement content was mixed with sand. Uniaxial geogrids with three different strengths were utilized to create the CTSG samples. The number of reinforcement layers, including single and double reinforcements, was studied. The image processing method was applied to analyze the surface cracks in the specimens. The results show that the geogrid type and the number of reinforcement layers affect the flexural behavior of the CTSG. Geogrid reinforcement changed the behavior of the CTS from a brittle material to a semi-brittle or ductile material because the residual tensile stresses were carried by the geogrids. The high-strength geogrid with a double reinforcement layer proved to be most effective in enhancing the peak strength and toughness with improvement ratios of 1.80 and 11.7, respectively. Single and double reinforcement layers with all geogrid types can reduce surface cracks with average crack reduction ratios of 64% and 83%, respectively. The CTSG can be successfully used as a sub-base layer to increase flexural performance and the lifetime of pavement and railway structures.
More Related Videos
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Fiber Reinforced Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Design Example: Joints in Concrete Pavements
Contraction joints are typically formed by sawing a groove into the concrete shortly after it has hardened. This creates a weakened vertical plane, deliberately encouraging cracking at...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...

