Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Novel Application of Multiscale Cross-Approximate Entropy for Assessing Early Changes in the Complexity between
Wei-Min Liu1, Hsin-Ru Liu2, Po-Wei Chen3
1Department of Computer Science and Information Engineering, National Chung Cheng University, Chiayi 621301, Taiwan.
Abstract:
Cardiac autonomic neuropathy (CAN) is a common complication of diabetes mellitus, and can be assessed using heart rate variability (HRV) and the correlations between systolic blood pressure (SBP) and ECG R-R intervals (RRIs), namely baroreflex sensitivity (BRS). In this study, we propose a novel parameter for the nonlinear association between SBP and RRIs based on multiscale cross-approximate entropy (MS-CXApEn). Sixteen male adult Wistar Kyoto rats were equally divided into two groups: streptozotocin-induced diabetes and age-matched controls. RRIs and SBP were acquired in control rats and the diabetic rats at the onset of hyperglycemia and insulin-treated euglycemia to determine HRV by the ratio of low-frequency to high-frequency power (LF/HF) and Poincaré plot as SSR (SD1/SD2), BRS, and MS-CXApEn. SSR and BRS were not significantly different among the three groups. The LF/HF was significantly higher in the hyperglycemic diabetics than those in the controls and euglycemic diabetic rats. MS-CXApEn was higher in the diabetic hyperglycemic rats than the control rats from scales 2 to 10, and approached the values of controls in diabetic euglycemic rats at scales 9 and 10. Conclusions: We propose MS-CXApEn as a novel parameter to quantify the dynamic nonlinear interactions between SBP and RRIs that reveals more apparent changes in early diabetic rats. Furthermore, changes in this parameter were related to correction of hyperglycemia and could be useful for detecting and assessing CAN in early diabetes.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
08:08Using Wavelet Entropy to Demonstrate how Mindfulness Practice Increases Coordination between Irregular Cerebral and Cardiac Activities
Published on: May 10, 2017
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: