Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
From the Lab to Real Life: Monitoring Cardiorespiratory Fitness during the COVID-19 Pandemic through Wearable
Francesco Luciano1, Valentina Cenacchi2, Luca Ruggiero1
1Department of Pathophysiology and Transplantation, University of Milan, 20133 Milan, Italy.
Abstract:
COVID-19 containment measures hampered population cardiorespiratory fitness (which can be quantified as peak oxygen consumption (V.O2peak)) and the possibility to assess it using laboratory-based techniques. Although it is useful to ascertain the V.O2peak recovery after lockdowns, the community and most scientific institutions were unable to evaluate it. Wearable devices may provide the opportunity to estimate cardiorespiratory fitness outside of the laboratory, without breaking self-isolation; herein, we explore the feasibility of this approach. Fifteen healthy participants were tested every 2 weeks for 10 weeks during a reduction of containment measures after a strict lockdown. Physical activity levels were measured using the International Physical Activity Questionnaire-Short Form (IPAQ-SF). V.O2peak was estimated through a previously validated test based on the speed of a 60 m sprint run, the baseline-to-peak heart rate (HR) variation, and the velocity of HR decay after the sprint, and measured through a wearable HR monitor. Participants increased physical activity from the end of lockdown (1833 [917-2594] MET-min/week; median [1st quartile-3rd quartile]) until the end of follow-up (2730 [1325-3380] MET-min/week). The estimated V.O2peak increased by 0.24 ± 0.19 mL/(min*kg*week) (regression coefficient ± standard error). Based on previous knowledge on the impact of inactivity on V.O2peak, our study indicates that a 10-week period of reducing the stringency of containment measures may not be sufficient to counteract the detrimental effects of the preceding lockdown.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes