Related Experiment Video
Updated: Jun 26, 2026

Hybrid µCT-FMT imaging and image analysis
Published on: June 4, 2015
Control Systems with Tomographic Sensors-A Review
Jaroslav Hlava1, Shereen Abouelazayem1
1Institute of Mechatronics and Computer Engineering, Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, 461 17 Liberec, Czech Republic.
Abstract:
Industrial process tomography offers two key advantages over conventional sensing systems. Firstly, process tomography systems provide information about 2D or 3D distributions of the variables of interest. Secondly, tomography looks inside the processes without penetrating them physically, i.e., sensing is possible despite harsh process conditions, and the operation of the process is not disturbed by intrusive sensors. These advantages open new perspectives for the field of process control, and the potential of closed-loop control applications is one of the main driving forces behind the development of industrial tomography. Despite these advantages and decades of development, closed-loop control applications of tomography are still not really common. This article provides an overview of the current state-of-the-art in the field of control systems with tomographic sensors. An attempt is made to classify the different control approaches, critically assess their strengths and weak points, and outline which directions may lead to increased future utilization of industrial tomography in the closed-loop feedback control.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Control Systems
At the heart...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Imaging Studies III: Computed Tomography

