Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Prescreening for osteoporosis with forearm bone densitometry in health examination population
Chun Yue1, Na Ding1, Lu-Lu Xu1
1Health Management Center, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China.
Background:
Early detection and timely prophylaxis can retard the progression of osteoporosis. The purpose of this study was to determine the validity of peripheral Dual Energy X-ray Absorptiometry (DXA) test for osteoporosis screening. We examined peripheral bone mineral density (BMD) using AKDX-09 W-I DXA densitometer. Firstly, we acquired BMD data from manufacturer-supplied density-gradient phantoms and 30 volunteers to investigate its accuracy and precision, then we measured BMD for 150 volunteers using both AKDX (left forearm) and Hologic Discovery Wi (left forearm, left hip and L1 - L4 vertebrae) simultaneously. Correlation relationship of BMD results acquired from two instruments was assessed by simple linear regression analysis, the Receiver Operating Characteristic (ROC) curves and Areas Under the Curves (AUCs) were evaluated for the diagnostic value of left forearm BMD measured by AKDX in detecting osteoporosis.
Results:
In vitro precision errors of AKDX BMD were 0.40, 0.20, 0.19%, respectively, on low-, medium-, and high-density phantom; in vivo precision was 1.65%. Positive correlation was observed between BMD measured by AKDX and Hologic at the forearm (r = 0.670), L1-L4 (r = 0.430, femoral neck (r = 0.449), and total hip (r = 0.559). With Hologic measured T-score as the gold standard, the sensitivity of AKDX T-score < - 1 for identifying suboptimal bone health was 63.0 and 76.1%, respectively, at the distal one-third radius and at any site, and the specificity was 73.9 and 90.0%, respectively; the AUCs were 0.708 and 0.879. The sensitivity of AKDX T-score ≤ - 2.5 for identifying osteoporosis at the distal one-third radius and at any site was 76.9 and70.4%, respectively, and the specificity was 80.4 and 78.0%, respectively; the AUCs were 0.823 and 0.778.
Conclusions:
Peripheral DXA appears to be a reliable tool for prescreening for osteoporosis.
Related Concept Videos
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Pre-Procedural Guidelines for Assessing Blood Pressure
Essential Minerals for Bone Health
Calcium and Phosphorus
Calcium is a critical component of bones, especially in the form of calcium phosphate and calcium carbonate. Since the body cannot make calcium, it must be obtained from the diet. However, calcium cannot be absorbed from the small intestine without...
Study Designs in Epidemiology
Observational studies are those where the researcher does not intervene but rather observes natural variations. They include cross-sectional, cohort, and...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
What is the Skeletal System?