Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions
Published on: January 7, 2019
A statistic comparison of multi-element analysis of low atmospheric fine particles (PM2.5) using different
Minkang Zhi1, Kai Zhang1, Xi Zhang2
1State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
Abstract:
Over the past few decades, the metal elements (MEs) in atmospheric particles have aroused great attention. Some well-established techniques have been used to measure particle-bound MEs. However, each method has its own advantages and disadvantages in terms of complexity, accuracy, and specific elements of interest. In this study, the performances of inductively coupled plasma-optical emission spectrometry (ICP-OES) and total reflection X-ray fluorescence spectroscopy (TXRF) were evaluated for quality control to analyze data accuracy and precision. The statistic methods (Deming regression and significance testing) were applied for intercomparison between ICP-OES and TXRF measurements for same low-loading PM2.5 samples in Weizhou Island. The results from the replicate analysis of standard filters (SRM 2783) and field filters samples indicated that 10 MEs (K, Ca, V, Cr, Mn, Fe, Ni, Cu, Zn, and Pb) showed good accuracies and precision for both techniques. The higher accuracy tended to the higher precision in the MEs analysis process. In addition, the interlab comparisons illustrated that V and Mn all had good agreements between ICP-OES and TXRF. The measurements of K, Cu and Zn were more reliable by TXRF analysis for low-loading PM2.5. ICP-OES was more accurate for the determinations for Ca, Cr, Ni and Pb, owing to the overlapping spectral lines and low sensitivity during TXRF analysis. The measurements of Fe, influenced by low-loading PM2.5, were not able to determine which instrument could obtain more reliable results. These conclusions could provide reference information to choose suitable instrument for the determination of MEs in low-loading PM2.5 samples.
More Related Videos
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Spectroscopy: Absorption, Emission, and Fluorescence