Related Experiment Video
Updated: Sep 25, 2025

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Effect of Pulse Indicator Continuous Cardiac Output Monitoring on Septic Shock Patients: A Meta-Analysis
Bin Wang1, Lijuan Cai1, Bin Lin1
1Emergency Department, The Third Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou City, 310000 Zhejiang Province, China.
Background:
Septic shock (SS) is the most common severe syndrome in the Intensive Care Unit (ICU). Enhancing the monitoring of hemodynamic indexes in SS patients carries huge clinical implications for reducing patient mortality. Recently, pulse indicator continuous cardiac output (PICCO) has been widely used in clinical practice, but its advantages than central venous pressure (CVP) in guiding the treatment of SS patients remains to be refined. Therefore, this study is aimed at assessing the clinical effects of PICCO in the treatment of patients with SS.
Methods:
The authors systematically searched several databases (PubMed, EMBASE, Cochrane Library, and China National Knowledge) between January 2001 and February 2021. When searching for relevant articles, the authors combined the following phrases describing the monitoring group ("pulse indicator continuous cardiac output," "central venous pressure") with the disease of interest as well as management ("SS," "sepsis"). The outcomes were independently assessed by two reviewers who scored the articles for methodological quality using the Cochrane Collaboration's "risk of bias" tool. Forest plots, as well as sensitivity and bias analyses, were carried out for the included articles. The primary outcome measures were length of ICU stay, duration of mechanical ventilation, 28-day mortality, and fluid resuscitation volume.
Results:
Ten studies comprising 350 cases monitored with PICCO and 373 cases monitored with traditional CVP were eventually identified. PICCO-monitored patients were observed to be significantly associated with shorter ICU stay than CVP-monitored patients (MD: -3.04, 95% CI: -4.74 to -1.34, P = 0.0005), shorter time of mechanical ventilation (MD: -1.84, 95% CI: -2.80 to -0.87, P = 0.0002), and lower 28-day mortality (RR: 0.67, 95% CI: 0.48 to 0.94, P = 0.02). The two groups showed no significant difference in subgroup analysis for fluid resuscitation volumes (P > 0.05).
Conclusion:
PICCO monitoring technique can significantly improve the prognosis of SS patients, shorten the time of mechanical ventilation and ICU stay, and reduce the 28-day mortality, which has positive guiding significance for patients with SS. Given the limitations of the quantity and quality of included studies, further research is warranted to verify the conclusions.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Measurement of Blood Pressure